The HI98713 Precision ISO Turbidity Portable Meter is specially designed for water quality measurements, providing reliable and accurate readings, even within low turbidity ranges. The instrument is based on a state-of-the-art optical system which guarantees accurate results, assures long term stability, and minimizes stray light and color interferences. Periodic calibration with the supplied standards compensates for any variations in intensity of the LED light source. The 25 mm round cuvettes composed of special optical glass guarantee the repeatability of turbidity measurements.
Kami juga menyediakan berbagai macam Alat uji untuk kualitas air, seperti : pH Meter, Conductivity Meter, DO Meter, TDS Meter, BOD / COD Meter, Spectrophotometer. Kami melayani penjualan untuk pengiriman seluruh Indonesia. Kami juga melayani Jasa Perbaikan, Instalasi dan Training Alat Laboratorium yang kami suuplai.
Segera hubungi Bag. Marketing kami : 0818-822-488 untuk mendapatkan harga yang terbaik.
Features at-a-glance
Ratio Measurement Mode – The HI98713 measures turbidity using the ratio method with a 90° and 180° light detector for more accurate measurements. Turbidity measurements can be made in the 0.00 to 1000 FNU range.
Multiple reading modes – Normal measurement, continuous measurement, or signal averaging measurement are reading modes available.
ISO Compliant – The HI98713 meets and exceeds the requirements of ISO 7027 method for turbidity measurements by use of an infrared LED light source.
Calibration – The HI98713 has a powerful calibration function that compensates for variation in light intensity. The calibration can be done using the supplied calibration solutions or user-prepared standards. A two, three, or four-point turbidity calibration can be performed by using the supplied (<0.1, 15, 100 and 750 FNU) standards. Calibration points can be modified if user-prepared standards are used.
AMCO AEPA-1 Primary Turbidity Standard – The AMCO AEPA-1 supplied standards are recognized as a primary standard by the USEPA. These non-toxic standards are made of styrene divinylbenzene polymer spheres that are uniform in size and density. The standards are reusable and stable with a long shelf life.
Specification of HI98703 Turbidity Meter :
Specification Name
Detail
sku
HI98713-02
FNU Range
0.00 to 9.99 FNU
10.0 to 99.9 FNU
100 to 1000 FNU
FNU Resolution
0.01 FNU from 0.00 to 9.99 FNU
0.1 FNU from 10.0 to 99.9 FNU
1 FNU from 100 to 1000 FNU
FNU Accuracy
±2% of reading plus 0.1 FNU
Range Selection
Automatic
Turbidity Repeatability
±1% of reading or 0.01 FNU, whichever is greater
Stray Light
< 0.1 FNU
Typical EMC Deviation
±0.05 FNU
Turbidity Light Detector
860 nm infrared LED
IR Detector
Silicon Photocell
Turbidity Method
Adaptation of ISO 7027, ratio method with 90° and 180° detector.
Turbidity Standards
< 0.1, 15, 100 and 750 FNU
Calibration
Two, three or four point calibration
Display
60 x 90 mm LCD with backlight
LOG Memory
200 records
Serial Interface
RS232 and USB 1.1
Environment
0 to 50°C (32 to 122°F); max 95% RH non-condensing
Turbidity Meter HI98703 Hanna Instruments
Deskripsi
Jual Turbidity Meter HI98703, Hanna Instruments
Kami juga menyediakan berbagai macam Alat uji untuk kualitas air, seperti : pH Meter, Conductivity Meter, DO Meter, TDS Meter, BOD / COD Meter, Spectrophotometer. Kami melayani penjualan untuk pengiriman seluruh Indonesia. Kami juga melayani Jasa Perbaikan, Instalasi dan Training Alat Laboratorium yang kami suuplai.
Segera hubungi Bag. Marketing kami : 0818-822-488 untuk mendapatkan harga yang terbaik.
Features at-a-glance
Ratio Measurement Mode – The HI98713 measures turbidity using the ratio method with a 90° and 180° light detector for more accurate measurements. Turbidity measurements can be made in the 0.00 to 1000 FNU range.
Multiple reading modes – Normal measurement, continuous measurement, or signal averaging measurement are reading modes available.
ISO Compliant – The HI98713 meets and exceeds the requirements of ISO 7027 method for turbidity measurements by use of an infrared LED light source.
Calibration – The HI98713 has a powerful calibration function that compensates for variation in light intensity. The calibration can be done using the supplied calibration solutions or user-prepared standards. A two, three, or four-point turbidity calibration can be performed by using the supplied (<0.1, 15, 100 and 750 FNU) standards. Calibration points can be modified if user-prepared standards are used.
AMCO AEPA-1 Primary Turbidity Standard – The AMCO AEPA-1 supplied standards are recognized as a primary standard by the USEPA. These non-toxic standards are made of styrene divinylbenzene polymer spheres that are uniform in size and density. The standards are reusable and stable with a long shelf life.
Specification of HI98703 Turbidity Meter :
10.0 to 99.9 FNU
100 to 1000 FNU
0.1 FNU from 10.0 to 99.9 FNU
1 FNU from 100 to 1000 FNU
Jual Turbidity Meter HI98703, Hanna Instruments