Advanced Dissolved Oxygen Meter with Optical DO Probe (opdo®)
HI6421 includes Hanna’s HI7641133 optical dissolved oxygen probe (opdo®) that is based on the principle of fluorescence quenching. An immobilized Pt-based luminophore is excited by the light of a blue LED and emits a red light. As oxygen interacts with the luminophore it reduces the intensity and lifetime of the luminescence. The lifetime of the luminescence is measured by a photodetector and is used to calculate the dissolved oxygen concentration.
The probe is fitted with easy to use Smart Caps (HI764113-1) which lock in place and contain pre-loaded calibration coefficients that are automatically transmitted to the probe. The Smart Cap features an immobilized O₂ sensitive luminophore with rugged insoluble black oxygen permeable protective layer.
Kami juga menyediakan berbagai macam Alat uji untuk kualitas air, seperti : pH Meter, Conductivity Meter, DO Meter, TDS Meter, BOD / COD Meter, Spectrophotometer. Kami melayani penjualan untuk pengiriman seluruh Indonesia. Kami juga melayani Jasa Perbaikan, Instalasi dan Training Alat Laboratorium yang kami suuplai.
Segera hubungi Bag. Marketing kami : 0818-822-488 untuk mendapatkan harga yang terbaik.
Measurement :
Application-specific profiles allow quick and direct measurement without the need to update the sensor and system settings
Active log during measurement
Measurement stability indicator (using the Stability Criteria setting)
Reading modes: direct and direct/autohold
Temperature compensation can be automatic or set manually
Audible and/or alarm messages for measurements outside of predefined limits
Galvanic isolation for measurement
Calibration
One or two points calibration at 0% and/or 100% saturation
Single point manual calibration in mg/L or % saturation using a reference method
Non-volatile memory saves data and settings
Zero Oxygen Calibration Solution
When performing a DO calibration, it is important that the correct standards are used. We include some starter solution to get you going. HI7040L is a bi-component zero oxygen solution designed so you can quickly calibrate to 0% oxygen concentration.
Logging
Data log collection of up to 1,000,000 data points (with time and date stamp)
Logging types: manual, automatic, autohold
Sample ID for manual and autohold data
Specification :
Specification Name
Detail
SKU
HI6421-01
DO Range
HI6421 – HI7641133 Optical probe: 0.00 to 50.00 mg/L (ppm) concentration; 0.0 to 500.0% saturation HI6421P – HI764833 Polarographic probe: 0.00 to 90.00 mg/L (ppm) concentration; 0.0 to 600.0% saturation
DO Accuracy (@25˚C/77˚F)
HI6421 – HI7641133 Optical probe: from 0.00 to 20.00 mg/L (ppm) 1.5 % of reading or ± 0.01 mg/L (ppm), whichever is greater
from 20.00 to 50.00 mg/L (ppm) ±5% of reading
from 0.0 to 200.0% saturation ± 1.5% of reading or ± 0.1%, whichever is greater
from 200.0 to 500.0% saturation ±5% of reading HI6421P – HI764833 Polarographic probe: ±1.5 % of reading ±1, least significant digit
DO optical:
One or two points automatic calibration at 100% (8.26 mg/L) and 0% (0 mg/L).
Single point manual using a value entered by the user in % saturation or mg/L.
DO polarographic:
Automatic-two points / User standard-single point
Barometric Pressure Range
450 to 850 mmHg; 600 to 1133 mBar; 60 to 133 kPa;
17 to 33 inHg; 8.7 to 16.4 psi; 0.592 to 1.118 atm
Barometric Pressure Resolution
1 mmHg; 1 mBar; 1 kPa; 1 inHg; 0.1 psi; 0.001 atm
Barometric Pressure Accuracy
±3 mmHg within ±15 % from the calibration point;
±3 mmHg ±1 least significant digit
Temperature Range
−20.0 to 120.0 °C
−4.0 to 248.0 °F
253.0 to 393.0 K
DO Meter HI6421 – Hanna Instruments
Advanced Dissolved Oxygen Meter with Optical DO Probe (opdo®)
HI6421 includes Hanna’s HI7641133 optical dissolved oxygen probe (opdo®) that is based on the principle of fluorescence quenching. An immobilized Pt-based luminophore is excited by the light of a blue LED and emits a red light. As oxygen interacts with the luminophore it reduces the intensity and lifetime of the luminescence. The lifetime of the luminescence is measured by a photodetector and is used to calculate the dissolved oxygen concentration.
The probe is fitted with easy to use Smart Caps (HI764113-1) which lock in place and contain pre-loaded calibration coefficients that are automatically transmitted to the probe. The Smart Cap features an immobilized O₂ sensitive luminophore with rugged insoluble black oxygen permeable protective layer.
Deskripsi
Jual DO Meter HI6421 – Hanna Instruments.
Kami juga menyediakan berbagai macam Alat uji untuk kualitas air, seperti : pH Meter, Conductivity Meter, DO Meter, TDS Meter, BOD / COD Meter, Spectrophotometer. Kami melayani penjualan untuk pengiriman seluruh Indonesia. Kami juga melayani Jasa Perbaikan, Instalasi dan Training Alat Laboratorium yang kami suuplai.
Segera hubungi Bag. Marketing kami : 0818-822-488 untuk mendapatkan harga yang terbaik.
Measurement :
Calibration
Zero Oxygen Calibration Solution
When performing a DO calibration, it is important that the correct standards are used. We include some starter solution to get you going. HI7040L is a bi-component zero oxygen solution designed so you can quickly calibrate to 0% oxygen concentration.
Logging
Specification :
HI6421P – HI764833 Polarographic probe: 0.00 to 90.00 mg/L (ppm) concentration; 0.0 to 600.0% saturation
from 20.00 to 50.00 mg/L (ppm) ±5% of reading
from 0.0 to 200.0% saturation ± 1.5% of reading or ± 0.1%, whichever is greater
from 200.0 to 500.0% saturation ±5% of reading
HI6421P – HI764833 Polarographic probe: ±1.5 % of reading ±1, least significant digit
HI6421P – HI764833 Polarographic probe: 0.01 mg/L (ppm); 0.1% saturation
One or two points automatic calibration at 100% (8.26 mg/L) and 0% (0 mg/L).
Single point manual using a value entered by the user in % saturation or mg/L.
DO polarographic:
Automatic-two points / User standard-single point
17 to 33 inHg; 8.7 to 16.4 psi; 0.592 to 1.118 atm
±3 mmHg ±1 least significant digit
−4.0 to 248.0 °F
253.0 to 393.0 K
HI6421P: HI764833 Polarographic probe
HI6421P is supplied with HI764833 polarographic probe; HI764060 electrode holder; capillary pipette; 24 VDC power adapter; USB-C to USB-A cable; probe quality certificate; quick reference guide with instrument quality certificate.
Jual DO Meter HI6421 – Hanna Instruments
Produk Terkait
pH Meter HI8424 Hanna Instruments
Info HargaAutomatic Potentiometric Titrator HI-932 – Hanna Instruments
Info HargapH Meter untuk Kulit HI99181 – Hanna Instruments